When designing laboratory air conditioning systems, both the complication of the temperature and humidity were considered. If the air is within the desired temperature values, it should be ensured that the humidity is controlled and drawn to the appropriate values. Thanks to the laboratory systems, the air flow in the environment should be distributed homogeneously and should not disturb the laboratory workers. Laboratory air conditioning, Tests and analysis of the substances and products to be produced in the laboratory should be done in conditions suitable for the laboratory environment, so that they can give clear results. Because, according to the certification systems, the tests and tests that are provided with humidity and temperature ratio are considered valid. This is provided by air conditioning systems.
What Should Be Considered In Laboratory Air Conditioning Systems?
Precision Controlled Air Conditioner Cooling Load Selection: Choosing the cooling load is one of the most important issues to be considered. When choosing these devices, a correct and detailed calculation should be made because it is important in terms of getting the efficiency you want. You should pay attention to the fact that there is a suitable capacity moisture cylinder in the devices selected especially considering the humidity values.
Outdoor Unit Selection: Outdoor units; selected by taking into account regional features. The most suitable outdoor unit device should be selected in order to make the heat exchange with the outdoor environment healthy. It should not be overlooked how the outdoor temperature will be according to the summer and winter temperatures. For example, the outdoor unit to be used in Aegean Region and Eastern Anatolia Region should be different from each other.
Device Selection: Dehumidification and dehumidification devices should be selected. In order to keep the moisture balance constant, devices with hot gas or inventer compressors should be used. Positioning after the supply of the device is another important issue. In positioning, particular attention should be paid to the homogeneous distribution of the air flow.
Hot Gas Devices: These devices are produced especially for laboratories and processes where humidity value is important. Thanks to the serpentine, which is additionally placed in hot gas laboratory air conditioning systems, it approaches the ambient temperature set value. In addition, in order not to decrease the temperature, the amount of gas directed out is sent to the coil and a balanced cooling is provided.
Inventer Compressor: Inventer compressors can increase or decrease gradually according to the cooling requirement of the environment. It prevents the compressors from consuming high energy during the first start and ensures the temperature of the cooled environment to remain constant.